Set Mode of IO Port

  • Function:

    magician.set_multiplexing(io, multiplex)
    
  • Description: set mode of IO port

  • Required parameter:

    • io: io port number, data type: str, range: "DO_01"~"DO_20"
    • multiplex: mode of IO port, range: 0~6
      • 0: IOFunctionDummy, no function configured
      • 1: IOFunctionDO, IO output
      • 2: IOFunctionPWM, PWM output
      • 3: IOFunctionDI, IO input
      • 4: IOFunctionADC, AD input
      • 5: IOFunctionDIPU, pull-up input
      • 6: IOFunctionDIPD, pull-down input
  • Return:
    • True: The command has been finished.
    • False: The command has not been finished.
  • Example

    magician.set_multiplexing(io="DO_01", multiplex=1)
    

    Set the mode of DO_01 port as IO output.

results matching ""